Elite X has 2 low side outputs and 2 PWM or frequency outputs. Configure each in the app by choosing its function, its trigger condition and, for PWM outputs, the frequency and duty.
Low side outputs switch a relay or a solenoid. They do not supply power. Wire the load to 12V and let the output provide the ground path.
Typical output functions:
- Cooling fan control
- Fuel pump control
- Water pump control
- Intercooler pump control
- Compressor control
- Warning light control
- Relay and solenoid control
Steps:
- Wire the load between 12V and the low side output.
- In the app, select the output and set its function.
- Set the trigger condition, for example coolant temperature above a set value.
- For PWM outputs, set frequency and duty.
- Check output diagnostics for a fault on that channel.
⚠️ Fit a flyback diode across any relay or solenoid coil. Switching an inductive load without one generates a voltage spike that damages the output.
Related: Elite X Connector A Pinout · How to Set Up an Analog Sensor on Elite X · What the Elite X Smart Control Module Does